NOTE: Email support_preciseflex@brooksautomation.com for help resolving error codes.
| Code | Text | Description |
|---|---|---|
|
-4000 |
Cannot connect to vision server |
GPL cannot establish an Ethernet TCP connection with the Precise Vision software on the vision host PC. If the web interface is not working, check the basic Ethernet connectivity. In addition, verify that the "Vision Server IP address" (DataID 424) is set properly for your vision host PC. Make sure that Precise Vision is active on that PC. |
|
-4001 |
Invalid vision protocol |
GPL is unable to decode a message received from PreciseVision. Verify that the versions of GPL and PreciseVision are compatible. If so, please report this error to customer service. |
|
-4002 |
Vision interlocked |
The communications link to PreciseVision is being used by a different GPL thread. Only one thread may access vision at a time. Stop any other threads that may be accessing PreciseVision. |
|
-4003 |
Vision interlocked |
|
|
-4010 |
Vision invalid protocol |
PreciseVision is unable to decode a message received from GPL. Verify that the versions of GPL and PreciseVision are compatible. If so, please report this error to customer service. |
|
-4011 |
Vision internal error |
An unexpected error has occurred within PreciseVision. Please report this error to customer service |
|
-4012 |
Vision unknown process |
A GPL vision method has specified a vision process that is not defined in the current PreciseVision project. Verify that the correct GPL project and PreciseVision project are loaded. |
|
-4013 |
Vision unknown tool |
A GPL vision method has specified a vision tool that is not defined in the current PreciseVision project. Verify that the correct GPL project and PreciseVision project are loaded. |
|
-4014 |
Vision invalid index |
A GPL vision Result method has specified an index for a result that does not exist. Verify that the correct GPL project and PreciseVision project are loaded. Verify the number of results returned by the current vision process. |
|
-4016 |
Vision invalid arguments |
The argument values specified in a vision ToolProperty method are not valid for that property. |
|
-4017 |
Vision property not found |
The property name specified in a vision ToolProperty method does not exist. Verify that the correct GPL project and PreciseVision project are loaded. |
|
-4018 |
Vision property protected |
An attempt has been made to change a vision tool property than cannot be modified. |
|
-4019 |
Vision process failed |
Execution of a selected process within PreciseVision has failed. This is normally due to the acquisition operation failing. |
|
-4020 |
Vision invalid calibration type |
A remote request to execute a vision calibration procedure failed because an invalid calibration type was specified. Set the calibration type to a valid type and try again. |
|
-4021 |
Vision invalid project name |
A remote request to load a vision project failed. Probably the project name was not valid. Verify that the name specified is correct and that the file exists in the correct location. |
|
-4022 |
Vision calibration file not found |
A remote request to load a vision calibration file failed because the calibration file could not be found. Verify that the file name specified is correct and that the file exists in the correct location. |
|
-4023 |
Vision project not saved |
A remote request to load a new vision project has failed because the current project has not been saved. Save the current project before attempting to load a new one. |