Code Text Description

-4000

Cannot connect to vision server

GPL cannot establish an Ethernet TCP connection with the Precise Vision software on the vision host PC. If the web interface is not working, check the basic Ethernet connectivity. In addition, verify that the "Vision Server IP address" (DataID 424) is set properly for your vision host PC. Make sure that Precise Vision is active on that PC.

-4001

Invalid vision protocol

GPL is unable to decode a message received from PreciseVision. Verify that the versions of GPL and PreciseVision are compatible. If so, please report this error to customer service.

-4002

Vision interlocked

The communications link to PreciseVision is being used by a different GPL thread. Only one thread may access vision at a time. Stop any other threads that may be accessing PreciseVision.

-4003

Vision interlocked

 

-4010

Vision invalid protocol

PreciseVision is unable to decode a message received from GPL. Verify that the versions of GPL and PreciseVision are compatible. If so, please report this error to customer service.

-4011

Vision internal error

An unexpected error has occurred within PreciseVision. Please report this error to customer service

-4012

Vision unknown process

A GPL vision method has specified a vision process that is not defined in the current PreciseVision project.  Verify that the correct GPL project and PreciseVision project are loaded.

-4013

Vision unknown tool

A GPL vision method has specified a vision tool that is not defined in the current PreciseVision project.  Verify that the correct GPL project and PreciseVision project are loaded.

-4014

Vision invalid index

A GPL vision Result method has specified an index for a result that does not exist. Verify that the correct GPL project and PreciseVision project are loaded. Verify the number of results returned by the current vision process.

-4016

Vision invalid arguments

The argument values specified in a vision ToolProperty method are not valid for that property.

-4017

Vision property not found

The property name specified in a vision ToolProperty method does not exist. Verify that the correct GPL project and PreciseVision project are loaded.

-4018

Vision property protected

An attempt has been made to change a vision tool property than cannot be modified.

-4019

Vision process failed

Execution of a selected process within PreciseVision has failed.  This is normally due to the acquisition operation failing.

-4020

Vision invalid calibration type

A remote request to execute a vision calibration procedure failed because an invalid calibration type was specified. Set the calibration type to a valid type and try again.

-4021

Vision invalid project name

A remote request to load a vision project failed. Probably the project name was not valid. Verify that the name specified is correct and that the file exists in the correct location.

-4022

Vision calibration file not found

A remote request to load a vision calibration file failed because the calibration file could not be found. Verify that the file name specified is correct and that the file exists in the correct location.

-4023

Vision project not saved

A remote request to load a new vision project has failed because the current project has not been saved. Save the current project before attempting to load a new one.