| ID | Label | Type | #Val | Min | Max | Attr | Description |
|---|---|---|---|---|---|---|---|
|
12200 |
Encoder software status word |
Uint32 |
|
|
|
RO |
Encoder software status word. The bit definitions are as follows: |
|
12201 |
Encoder time-stamp |
Uint32 |
|
|
|
RO |
Time-stamp when the encoder reading is latched. This is not used for an incremental encoder and is always 0. It will be used for an absolute encoder, specifically for a serial commutation type of encoder. The time stamp resolution is in micro-seconds, and potentially allows for jitter compensation to allow for more accurate velocity and accel feedback derivation. |
|
12202 |
Encoder position, ecnt |
Flt64 |
|
|
|
RO |
Encoder feedback position. This encoder value corresponds to the current axis position. |
|
12203 |
Encoder velocity, ecnt/sec |
Flt32 |
|
|
|
RO |
Encoder feedback velocity, unfiltered. |
|
12204 |
Motor position feedback, mcnt |
Flt64 |
|
|
|
RO |
Motor feedback position. Normally, the encoder to motor scale factor is 1 (DataID 10206), and the motor feedback position is the same as the encoder feedback position. |
|
12205 |
Motor velocity feedback, mcnt/sec |
Flt32 |
|
|
|
RO |
Motor feedback velocity, unfiltered. |
|
12206 |
Filtered motor velocity, mcnt/sec |
Flt32 |
|
|
|
RO |
Filtered motor feedback velocity. Refer to DataID 10207, "Motor velocity
SPR filter pole", for the filter setup. This filtered value is NOT used in the PID loop. This term is used for other purposes, such as: |
|
12207 |
Motor acceleration feedback, mcnt/sec^2 |
Flt32 |
|
|
|
RO |
Motor feedback acceleration. This value is derived from the filtered velocity feedback. However, due to the double differentiation of the position feedback, this value is typically very noisy. This data is only used during special resonance cancellation situations. |
|
12208 |
Scaled minor motor position, mcnt |
Flt64 |
|
|
|
RO |
(Dual-loop) Scaled minor motor position in the major motor space. |
|
12209 |
Position slippage of dual loop axis, mcnt |
Flt32 |
|
|
|
RO |
(Dual-loop) Position slippage amount between the major and minor encoders. This calculation is evaluated in the major motor space, i.e., the minor encoder position is scaled into the major motor. |
|
12210 |
Maximum position slippage amount, mcnt |
Flt32 |
|
|
|
|
(Dual-loop) Maximum position slippage observed so far. This variable may be reset during run-time to allow you to capture the maximum value over a new period of time. |
|
12211 |
Scaled minor motor speed, mcnt/sec |
Flt32 |
|
|
|
RO |
(Dual- loop) Scaled minor motor speed in the major motor space. |
|
12212 |
Speed slippage of dual loop axis, mcnt/sec |
Flt32 |
|
|
|
RO |
(Dual-loop) Speed slippage amount between the major and minor encoders. This calculation is evaluated in the major encoder space. |
|
12213 |
Maximum speed slippage amount, mcnt/sec |
Flt32 |
|
|
|
|
(Dual-loop) Maximum speed slippage observed so far. This variable may be reset during run-time to allow you to capture the maximum value over a new period of time. |
|
12215 |
Raw velocity from encoder, ecnt/sec |
Flt32 |
|
|
|
RO |
(EtherCAT) Raw velocity value read from EtherCAT slave motor drive. |