24VDC Controller Logic Power Connector

All of the controller's logic functions, the digital input and output signals, and the motor brakes are supplied power by the 24VDC Controller Logic Power Connector. As soon as this power is provided, the system begins its booting process. See the Guidance 1000 product specifications for information on the number of amperes that must be supplied. The connector is a two-pin AMP 3-794618-2, and the mating plug is an AMP 794617-2.

Figure 34-77: Two-pin AMP 3-794618-2 Connector and AMP 794617-2 Plug

Table 34-65: Pin Descriptions

Pin Description

1

+24VDC input

2

GND

User Plug Part No

AMP 794617-2. Use an AMP 91501-1 hand tool and AMP 1-794610-2 sockets for wiring to the plug.